Assembly Instructions for Vertical Immersion Pumps
Models SM-5 to SM-30
- Insert vapor seal (item 9) into seat of draft tube (item 4).
- Bolt draft tube (item 4) to "C" face of motor with four (4) each stainless steel bolts.
- Attach impeller to motor shaft using four (4) each setscrews with 1/64" space between impeller back veins and under surface of bottom flange.
- Mount volute case with gasket to draft tube with four (4) each hex head cap screws - snug fit.
- Option - Attach hose adapter to overflow with threaded connection.
|